The owner of the villa has not yet lived as a dangerous house: the wall of the foundation is cracked.

category:Global
 The owner of the villa has not yet lived as a dangerous house: the wall of the foundation is cracked.


Although the construction of the foundation has begun, the owners believe that the patching does not cover up the quality defects of the building when the room is built, and they hope that the developer can give a reasonable statement. Subsoil subsidence of joint Villa A deep pit in the middle of the two building Fresh lady is an owner of 16 buildings in the three phase of eco international city district. Not long ago, she saw in the owner group other owners talking about the wall cracks in the house, and someone posted a test report in the group. I knew I had a problem with the house I bought, and the neighbour said that the construction team had been in my house and began to work. Fresh lady said, she rushed to the community, see construction has begun. The workers say it is because of the foundation subsidence to reinforce the construction. After communicating with other owners, she knew that the 15 and 16 middle positions were the most serious areas of settlement, and the cracks in the 16 106 room walls were very serious, and some of the doors and windows had been unable to be opened because of the wall deformation. Yesterday morning, the Chinese business newspaper reporters found that many of the walls of the wall cracks, dislocation, 16 of the 106 walls of the most serious wall damage, south of the door to the door has been unable to open. The test report thinks Subsoil immersion and subsoil inhomogeneity Developers looking for professional institutions have been identified, the conclusion is that our house has become a dilapidated house. 15 owners, Lao Jiao, who have checked in, have provided a copy of the test report to reporters. The report from the Shaanxi Construction Engineering Quality Inspection Center said that the 15 and 16 two buildings were found in the field and found that the construction of the two buildings met the requirements, but when the soil layer was tested, the filling layer was found to be mainly mixed and filled with a large number of brick tiles, plastic bags, concrete blocks, and some foam boards. Containing a small amount of silty clay. When excavating the well, the water was unable to be excavated, but the experiment was terminated. It is found that the cause of the wall cracking of the building is the foundation soaking and the unevenness of the foundation soil, and the compaction coefficient of the pile body of the two building is not satisfied with the specification and design requirements. The building tilt detection results show that the buildings are slightly inclined, but the maximum displacement meets the standard. The report mainly assessed the structural safety of the two buildings. According to the national standard reliability identification standard for civil buildings, the safety of the two building identification units was evaluated as grade Csu, that is, the safety does not conform to the standard stipulates, and the overall bearing capacity should be significantly affected, and the measures should be taken, and there may be very few construction needs. Measures should be taken in time. We are strengthening the foundations. The water pipes below the two buildings cause the foundation to sink and the walls to crack. Yesterday morning, the head of the construction team, Mr. Lin introduced that their construction plan is to use the thirty or forty cm diameter of the steel pipe into the underground, inside the concrete, straight to the hard soil or stone layer, the upper support housing, our construction standard is very high, the stability is very high, the individual crack may be supported and healed. Mr. Lin said that the project has millions of projects, the new house that the owner certainly does not want to buy will be repaired, but we can fully believe in the quality of our construction. Developer reply In accordance with the normal procedure, the claim will be compensated. In the interview, the owners think that their own millions of villas have not been occupied as dangerous houses, and the quality of the construction of the developers is seriously unqualified. Last night, the developer replied to the China Daily newspaper reporter that the government had asked professional agencies to carry out preliminary exploration at the beginning of the regional construction of the project. But because the area is located on the lakeside and the water is abundant, the present situation is caused. It is true that the foundation settlement has been caused by the cracks in the house, and the test has been done before, and the main body has nothing to do with it, but it only needs to do some repair work. The company has paid nearly 5 million of the price, the responsible person said. He said, the company is the pursuit of the quality of the project, the problem will face, will be further discussed with the owners, in accordance with the normal procedures, the compensation compensation, if the main return of the industry can also, in a word as far as possible to achieve the satisfaction of the owners. Reporters learned that the owners and developers to get in touch, the two sides agreed to conduct consultations in May 11th. Know a little bit What is the Csu level? In the four grades of Asu, Bsu, Csu and Dsu of the standard for the reliability identification of civil buildings, Asu grade (perfect) - the structural bearing capacity can meet the normal use requirements, no dangerous points are found, the structure of the house is safe, and the Bsu level (basically perfect) - the structure bearing base instinct satisfies the normal use requirements and individual knot Structural members are in a dangerous state, but they do not affect the main structure, basically meet the normal use requirements; Csu level (restricted use) - the bearing capacity of part bearing structure can not meet the normal requirements, local danger, form a local crisis, Dsu level (dangerous) bearing capacity of the bearing structure can not meet the normal use of the need. The whole house is in danger and constitutes a dangerous building. Housing that reaches the Csu level limit can not be rebuilt without being repaired or repaired. ?